Overview of Variable Refrigerant Flow Air Conditioning System
DOI:
https://doi.org/10.21063/jtm.2021.v11.i1.37-46Kata Kunci:
VRF system, Coefficient of performance, Control strategy, Thermal comfortAbstrak
Variable refrigerant flow air-conditioning (VRF) systems are important and widely used in building energy systems around the world. The system is gradually gaining popularity in commercial and residential buildings due to its satisfactory partial load performance, flexible control, ease of installation and maintenance. Variable refrigerant flow air-conditioning (VRF) is a multi-split Heating, Ventilation and Air Conditioning (HVAC) system that controls refrigerant flow to control separate zones for the needs of residential consumers and commercial buildings. The objective of this review is to identify VRF systems that affect various aspects of operation and performance. Special VRF components regulate refrigerant volume control for system performance and reliability. The findings show that specific testing through different compressor settings, electronic expansion valve (EEV) position, and airflow operation affects performance, thermal comfort and potential energy savings. The main conclusions drawn from this detailed review provide a comprehensive overview of VRF and inspire new insights and viable solutions for relevant researchers, product developers, practitioners and policy makers in this field. Previous experimental investigations will be more helpful in the future direction of progress as the development of an extensive VRF system is still in the main stages.
Referensi
N. Enteria and K. Mizutanit. The role of the thermally activated desiccant cooling technologies in the issue of energy and environment. Renew Sustain Energy Rev 2011; 15:2095–122.
R. Qi, L. Lu and H. Yang. Investigation on air-conditioning load profile and energy consumption of desiccant cooling system for commercial buildings in Hong Kong. Energy Build 2012; 49:5018.
L. Perez-lombard, J. Ortiz and C.A. Pout. review on buildings energy consumption information. Energy Build 2008; 40:394–8.
Y. Yao and J. Chen. Global optimization of a central air-conditioning system using decomposition–coordination method. Energy Build 2010; 42:570–83.
C.A. Balaras, G. Grossman, H. Henning, C.A.I. Ferreira, E. Podesser, L. Wang, et al. Solar air conditioning in Europe – an overview. Renew Sustain Energy Rev 2007; 11:299–314.
Australian Greenhouse Office. Australian Commercial Building Sector Green- House Gas Emission. AGO, Canberra, Australia; 1990–2010.
Energy Conversation Building Code (ECBC). Bureau of Energy Efficiency, Ministry of Power, Government of India; 2007.
K.F. Fong, T.T. Chow, C.K. Lee, Z. Lin and L.S. Chan. Comparative study of different solar cooling systems for buildings in subtropical city. Sol Energy 2010; 84:227–44.
H. El-Dessouky, H. Ettouney, A. Al-Zeefari. Performance analysis of two-stage evaporative coolers. Chem Eng. J 2004; 102:255–66.
IEO, International Energy Outlook (IEO), Energy Information Administration<http://www.eia.doe.gov/oiaf/ieo>.
U. Desideri, S. Proietti and P. Sdringola. Solar powered cooling system: technical and economic analysis on industrial refrigeration and air conditioning applications. Appl Energy 2009; 86:1376–86.
Q. Ma, R.Z. Wang, Y.J. Dai and X.Q. Zhai. Performance analysis on a hybrid air conditioning system of a green building. Energy Build 2006; 38:447–53.
ANSI/ASHRAE Standard 55–2004. Thermal Environmental Conditions for Human Occupancy, American Society of Heating Ventilating and Air Conditioning Engineers, Atlanta, GA, USA; 2004.
A. Yildiz, M. Ali Ersöz, Determination of the economical optimum insulation thickness for VRF (variable refrigerant flow) systems, Energy 89 (2015) 835–844.
N. Enteria, H. Yamaguchi, M. Miyata, T. Sawachi, Y. Kuwasawa, Performance evaluation of the variable refrigerant flow (VRF) air-conditioning system subjected to partial loadings at different outdoor air temperatures, J. Therm. Sci. Tech. 11 (2) (2016).
G. Zhang, W. Liu, H. Xiao, W. Shi, B. Wang, X. Li, Y. Cao, New method for measuring field performance of variable refrigerant flow systems based on compressor set energy conservation, Appl. Therm. Eng. 154 (2019) 530–539.
D. Zhao, M. Zhong, X. Zhang, X. Su, Energy consumption predicting model of VRV (Variable refrigerant volume) system in office buildings based on data mining, Energy 102 (2016) 660–668.
Z. Li, B. Wang, X. Li, W. Shi, S. Zhang, Y. Liu, Simulation of recombined house- hold multi-split variable refrigerant flow system with split-type air conditioners, Appl. Therm. Eng. 117 (2017) 343–354.
M.S. Elliott, B.P. Rasmussen, Decentralized model predictive control of a multi-evaporator air conditioning system, Control Eng. Pract. 21 (12) (2013) 1665–1677.
H. Cheung, J.E. Braun, Component-based, Gray box modelling of ductless multi-split heat pump systems, Int. J. Refrig. 38 (2014) 30–45.
H. Liu, G. Ma, S. Shao, B. Fan, Performance investigation on refrigeration and air conditioning systems with multi-evaporator, Sustain. Cities Soc. 39 (2018) 605–612.
Q. Tu, Z. Feng, S. Mao, K. Dong, R. Xiao, W. Song, Heating control strategy for variable refrigerant flow air conditioning system with multi-module outdoor units, Energy Build. 42 (11) (2010) 2021–2027.
X. Lin, H. Lee, Y. Hwang, R. Radermacher, A review of recent development in variable refrigerant flow systems, Sci. Tech. Built Environ. 21 (7) (2015) 917–933.
X. Lin, J. Ling, Y. Hwang, R. Radermacher, B. Kim, Improvement of variable refrigerant flow system performance using energy saving control strategy and chilled water storage, Sci. Tech. Built Environ. 24 (5) (2018) 483–491.
D.Y. Park, G. Yun, K.S. Kim, Experimental evaluation and simulation of a variable refrigerant flow (VRF) air-conditioning system with outdoor air processing unit, Energy Build. 146 (2017) 122–140.
R. Zhang, K. Sun, T. Hong, Y. Yura, R. Hinokuma, A novel variable refrigerant flow (VRF) heat recovery system model: development and validation, Energy Build. 168 (2018) 399–412.
T. Hong, K. Sun, R. Zhang, R. Hinokuma, S. Kasahara, Y. Yura, Development and validation of a new variable refrigerant flow system model in EnergyPlus, Energy Build. 117 (2016) 399–411.
M.H. Chung, Y.K. Yang, K.H. Lee, J.H. Lee, J.W. Moon, Application of artificial neural networks for determining energy efficient operating set-points of the VRF cooling system, Build. Environ. 125 (2017) 77–87.
L. Kwon, Y. Hwang, R. Radermacher, and B. Kim, 2012. Field performance measurement of a VRF system with sub-cooler in educational building for the cooling season. Energy Build. 49, 300–305.
C. Kwon, M.S. Kim, Y. Choi and M.S. Kim, 2017. Performance evaluation of a vapor injection heat pump system for electric vehicles. Int. J. Refrig. 74, 138–150.
Z. Li, B. Wang, X. Li and W. Shi. 2016. Simulation on effects of sub cooler on cooling performance of multi-split variable refrigerant flow systems with different lengths of refrigerant pipeline. Energy Build. 126, 301–309.
Q. Tu, L. Zhang, W. Cai, X. Guo, C. Deng, J. Zhang and B. Wang, 2017. Effects of sub– cooler on cooling performance of variable refrigerant flow air conditioning system. Appl. Therm. Eng. 127, 1152–1163.
X. Wang, Y. Hwang R. Redermacher, 2009. Two-stage heat pump system with vapor-injection scroll compressor using R410A as a refrigerant. Int. J. Refrig. 32 (6), 1442–1451.
I. Cho, H. Seo, D. Kim, D and Y. Kim, 2016. Performance comparison between R410A and R32 multi-heat pumps with a sub-cooler vapor injection in the heating and cooling modes. Energy 112, 179–187.
H. Yan and S. Deng, "Simulation Study on a Three-evaporator Air Conditioning System for Improved Humidity Control," Energy Procedia, vol. 105, pp. 2139-2144, 2017.
D. Park, G. Yun and K. Kim, "Experimental evaluation and simulation of a variable refrigerant- flow (VRF) air-conditioning system with outdoor air processing unit," Energy and Buildings, vol. 146, pp. 122-140, 2017.
A. Alahmer and S. Alsaqoor, "Simulation and optimization of multi-split refrigerant flow systems," Ain Shams Engineering Journal, vol. 9, pp. 1705-1715, 2018.
Q. Tu, L. Zhang, W. Cai, X. Guo, X. Yaun, C. Deng and J. Zhang, "Control strategy of compressor and sub-cooler in variable refrigerant flow air conditioning system for high EER and comfortable indoor environment," Applied Thermal Engineering, vol. 141, pp. 215-225, 2018.
S. Atas, M. Aktas, I. Ceylan and H. Dogan, "Development and Analysis of a Multievaporator Cooling System with Electronic Expansion Valves," Arabian Journal for Science & Engineering, vol. 42, pp. 4513-4521, 2017.
J. Xia, E. Winandy, B. Georges and J. Lebrun, "Testing Methodology for VRF Systems," in International Refrigeration and Air Conditioning Conference, 2002.
J. Choi and Y. Kim, "Capacity modulation of an inverter-driven multi-air conditioner using electronic expansion valves," Energy, vol. 28, pp. 141-155, 2003.
R. Saab, H. A. Quabeh and M. I. Hassan Ali, "Variable refrigerant flow cooling assessment in humid environment using different refrigerants," Journal of Environmental Management, vol. 224, pp. 243-251, 2018.
R. Saab and M. I. Hassan Ali, "Variable refrigerant flow cooling systems performance at different operation pressures and types of refrigerants," Energy Procedia, vol. 119, pp. 426432, 2017.
H. Cheung and J. E. Braun, "Performance comparisons for variable-speed ductless and single speed ducted residential heat pumps," International Journal of Refrigeration, vol. 47, pp. 15-25, 2014.
D. Zhang, X. Zhang and J. Liu, "Experimental study of performance of digital variable multiple air conditioning system under part load conditions," Energy & Buildings, vol. 43, pp. 1175-1178, 2011.
Y. Zhu, X. Jin, Z. Du, X. Fang, B. Fan, Control and energy simulation of variable refrigerant flow air conditioning system combined with outdoor air processing unit, Appl. Therm. Eng. 64 (2014) 385–395, https://doi.org/10.1016/j.applthermaleng.2013.12.076.
Y. Zhu, X. Jin, Z. Du, X. Fang, Online optimal control of variable refrigerant flow and variable air volume combined air conditioning system for energy saving, Appl.Therm. Eng. 80 (2015) 87–96, https://doi.org/10.1016/j.applthermaleng.2015.
S.H. Kim, H.J. Moon, Case study of an advanced integrated comfort control algorithm with cooling, ventilation, and humidification systems based on occupancy status, Build. Environ. 133 (2018)246–264, https://doi.org/10.1016/j.buildenv.2017.12.010.
J. Lee, H. Yoon, P. Im, Y. Song, Verification of energy reduction effect through control optimization of supply air temperature in VRF-OAP system, Energies 11 (2017) 49, https://doi.org/10.3390/en11010049.
T. Zakula, P.R. Armstrong, L. Norford, Advanced cooling technology with thermally activated building surfaces and model predictive control, Energy Build. 86 (2015) 640–650, https://doi.org/10.1016/j.enbuild.2014.10.054.
H.-C. Chuang, Y.-X. Zeng, C.-T. Lee, Study on a chiller of air conditioning system by sensing refrigerant pressure feedback control with stepless variable speed driving technology, Build. Environ. 149 (2019) 157–168, https://doi.org/10.1016/j.buildenv.2018.12.024.
Unduhan
Diterbitkan
Terbitan
Bagian
Lisensi
Hak Cipta (c) 2021 A. Rachman